image 2 image 4
Skip Navigation Links
 Home 
 Congress Structure 
 Important Dates 
 Venue 
 Registration 
 Pre Registered 
 Abstracts 
 Scientific Program 
 Exhibition 
 Contact Us 
 Personal page 
 Photo and Film Festival 
       XXVII Annual Congress of the Iranian Society of Ophthalmology        بـیــست و هفتمین کنــگــره سـالیـانه انـجـمـن چـشـم پـزشـکی ایـــران
مقاله Abstract


Title: Comparative of Scheimpflug imaging parameters between normal thickness cornea and thick cornea
Author(s): Leila Ghiasian MD, Rama Pourmatin MD, Khalil Ghasemi Falavarjani, MD.
Presentation Type: Oral
Subject: Cornea and Anterior Segment
Others:
Presenting Author:
Name: Leila Ghiasian
Affiliation :(optional) Eye Research Center, Rassoul Akram Hospital, Iran University of Medical Sciences
E mail: leilaghiasian@gmail.com
Phone: 22003464
Mobile: 09125334697
Purpose:

To compare the anterior and posterior corneal surface parameters, thickness profile data and BAD display data of normal thickness eyes with thick corneas using Pentacam

Methods:

In this study, 100 normal thickness corneas and 100 thick corneas (>600mic). A complete ophthalmic evaluation and a Scheimpfug camera scan were performed in every cornea included in the study. Tomographic parameters such as parameters from the front and back cornea, maximum keratometry reading (Kmax), corneal volume (CV), anterior chamber volume (ChV), anterior chamber depth (ACD), anterior chamber angle (AC angle), keratometric power deviation (KPD), maximum front elevation (Max FE), and maximum back elevation (Max BE), as well as pachymetric progression indices (PPI), Ambrosio relational thickness (ART), index of surface variance (ISV), index of vertical asymmetry (IVA), center keratoconus index (CKI), index of height asymmetry (IHA), index of height decentration (IHD), and radius minimum (RM) were collected and statistically compared between the two groups.

Results:

Mean thinnest in normal corneal thickness group and in thick cornea group was 5496.74 and 62211.34 respectively. Analysis showed significant differences (p<0.05) in Corneal volume, AC volume and AC angle between two groups which were more in thick cornea group than normal thickness group. Corneal volume, chamber volume and AC angle were 65.624.55,199.256.8,40.638.43 in thick cornea group respectively and 60.203.34,172.6437.78,35.385.44 in normal thickness group respectively. Analysis found significant differences in CKI, IHA, R.min, Df, Db, Da and D between these two groups but mean range of these data were in normal range.

Conclusion:

Pentacam parameters in both groups were the same as each other. Chamber volume and AC angle were significantly higher in thick cornea than normal thickness cornea.

Attachment:





Skip Navigation Links
        صفحه اصلی
        ساختار کنگره
        تاریخ های مهم
        مکان برگزاری
        ثبت نام
        ثبت نام شدگان
        اطلاعات هتل - رزرو
        مقالات
        برنامه کنگره
        جشنواره فیلم و عکس
        نمایشگاه
        تماس با ما
        صفحه شخصی
        جستجوی سخنران
        آرشیو کنگره سالهای گذشته
        شب کنگره چشم پزشکی
 
ورود شرکت کنندگان
نام کاربری :
کلمه عبور :
  کلمه عبور خود را فراموش کرده ام.
Total Visits
Find us on Social Media
Congress Count Down
Today Label
Last Month Label
Total Visitors Label